The visit has three parts: set-up, the treatment itself and the sign-off. Set-up means sheeting and making equipment safe, while signing off means the written report and pictures. Most of the time goes on the work itself, and that takes an hour or two for one fan, longer when it’s hard to reach. For a job in Brent Cross, tell us about loading bays, permits, lifts and roof access when you book.

  1. The fan is found and its type, access and isolation checked.
  2. It’s isolated so it cannot run while we work.
  3. We scrape the heavy grease from the blades and housing.
  4. The fan is degreased, taking care around the motor.
  5. We reassemble, run and photograph the fan.

How to prepare

  • Find the previous report, if there is one
  • Make sure someone can let us in and lock up afterwards
  • Clear the space around the work

Ask for a quote

Photos are the quickest way to a quote: the system from a couple of angles, plus any access panels or hatches. Add the site type and your opening hours, and many jobs can be priced from that alone.

Ask for a quote

Advice

How we handle extract fan cleaning in Brent Cross

Every TR19® Grease clean includes the extract fan, but some fans need cleaning between full cleans, especially when it has started to vibrate or sound rough. Where only the fan is cleaned, the report says so. Typical jobs include rough running from the extract fan and a heavily greased fan housing, across roof-mounted fans, fan housings and axial fans.

London kitchens are often tucked into basements or the back of a building, with extract ducts that can climb several floors to discharge at roof level. In Brent Cross, as elsewhere in the capital, a long duct run means more access points to open and more grease to remove.

Insurers, fire officers and environmental health officers all look at records. So every job comes with a written report and photos, and grease extract cleans come with a TR19® certificate issued through the BESCA Vent Hygiene Elite portal.

Location
Brent Cross (NW4, NW11, NW2)
Wider area
Greater London
Reporting
Certificate plus before-and-after pictures
Price
A fixed quote up front
Hours
Out of hours as standard, 24/7 emergency line
Call
0345 646 2711
Reviewed
30 October 2026
Five Duct Doctor technicians in navy uniforms with the company vans

Extract fan cleaning around Brent Cross

The Food Standards Agency lists about 15 pubs and bars and about 12 hotels, B&Bs and guest houses as registered food businesses within 1.5 miles or so of the middle of Brent Cross. Where they serve hot food, their kitchen extracts need cleaning to TR19® like any restaurant’s. Most London extract cleaning happens at night, after the last service. Kitchens in Brent Cross get their food hygiene inspections from Barnet council. The cleanliness of the kitchen and its equipment, extraction included, is part of what they check. Before-and-after photos from each clean are a simple way to show the extract is in hand.

If you run catering at a healthcare site, such as a hospital like St Andrew's Hospital about 1.2 miles south-west, the extract may need cleaning more often than a part-time kitchen. If you run catering at a historic house or estate in the area (Heath House is about 1.9 miles south-east), event kitchens in older buildings often have awkward duct runs that need planning.

Brent Cross is about 2 miles north-west of West Hampstead, in Greater London. From the centre of Brent Cross to the outskirts, extract fan cleaning is available to all kinds of commercial premises, from a single unit to a large public building. Across Greater London, we cover 764 places, Brent Cross among them. There’s also a page for London, about 8 miles away.

Every address in NW4, NW11 and NW2 is covered for extract fan cleaning, from the main roads to the quietest streets. Whether your site is on Park Road, Graham Road and Elliot Road or anywhere close by, our technicians can take on the work. Brent Cross sits on or near the A41, which makes travel easy for extract fan cleaning. Nearby, we also carry out extract fan cleaning in Hendon (1 mile north), Staples Corner (1 mile south-west), The Burroughs (1 mile north-west), Dollis Hill (1 mile south-west) and The Hyde (1 mile west). We also work in nearby towns such as London (8 miles south-east), City of Westminster (5 miles south-east), Marylebone (5 miles south-east), Kensington (5 miles south), St Pancras (6 miles south-east) and Shoreditch (7 miles south-east).

Around Brent Cross

Locally, jobs take us to businesses close to Kisharon College, Hasmonean Primary School and The White Bear pub and the streets around them. The closest station to Brent Cross is Brent Cross West station, about 0.7 miles south-west of the centre. Nearby you’ll also find St Andrew's Hospital (1.2 miles south-west) and Brent Cross Shopping Centre (within half a mile west). Green spaces nearby include Darland's Lake and Parliament Hill.

Map of Brent Cross © OpenStreetMap contributors

How the job changes from site to site

Inline duct fans

Inline fans sit within the duct run, often above a ceiling. We get to them through the duct or casing after isolating them.

Roof-mounted fans

Roof fans sit at the top of the riser. We clean them where they can be safely reached, and anything we can’t reach is recorded.

How we price extract fan cleaning

Sites vary more than people expect. What affects the quote:

  • The condition we find in the survey
  • Access, including roofs, risers and ceiling voids
  • Site requirements such as sign-in and permits
  • When the work can happen, such as evenings, overnight or weekends

Several systems or sites on one quote can make for a more efficient booking. Tell us about everything you’d like looked at, and you’ll get one fixed quote.

Helping us quote

The more you tell us, the more accurate the quote. When you get in touch, it helps to send:

  • Problems your staff have spotted
  • Wide photos of the system and the area around it
  • Detail shots of panels, filters and grilles
  • The times we could work without disrupting the site

We do not publish a price list, because no two systems are the same. Instead, we look at your site first, from photos or a survey, then send a fixed quote. To get going, phone us on 0345 646 2711, or send details by email.

FAQs for Brent Cross

How do you handle parking and loading in Brent Cross?

London parking can be tight, so details of loading bays and permits help. Night visits tend to make loading easier on London streets.

Who enforces fire safety at workplaces in Brent Cross?

It’s London Fire Brigade, which covers Brent Cross. TR19® isn’t law, but it’s the benchmark many fire officers and insurers look to when they ask how often the extract is cleaned.

What about areas you cannot get to?

Anything we can’t reach goes on the report, with a note of where it is, and we tell you what would make it reachable, such as extra access panels in ductwork.

Is TR19 cleaning required by law?

No. The law sets the duty, and TR19® is the recognised benchmark for meeting it. Under the Fire Safety Order 2005, the responsible person must reduce fire risk, and without records, many insurers may refuse or reduce a claim.

Can we book visits on a schedule?

Yes. Tell us what you have and how it’s used and we will propose a schedule with a fixed quote.

Is there a survey before the work?

Yes. For many sites, photos and a few details are enough, while bigger or harder-to-see systems are surveyed on site.

How do you protect the area?

With sheeting and covers, before anything else happens. The work is kept contained and clean down when we finish.

Are you insured?

Yes. Full insurance covers our work, and we’ve been trading since 2009.

What staff can safely do

Your own staff can handle the daily basics: wiping down canopy surfaces, cleaning filters and keeping a simple log. What they cannot safely do is clean inside the ductwork, the fan or the risers, and that is where we come in.

A few tasks are always specialist work: opening up ductwork, cleaning fans, drop testing fire dampers and measuring grease need training, the right equipment and safe access. Leave those to us.

Landlords, agents and facilities managers

Records are where multi-site compliance often slips. Every visit ends with a dated report and photos, ready to show insurers, fire officers or EHOs.

We work for landlords, managing agents and facilities managers as well as the people running the site. Shared systems, like a riser serving several units, need a clear agreement on who books the work, and we can quote for the whole system.

Common problems we fix in Brent Cross

The fan sits at the end of the grease’s journey. The grease that’s left lands on the blades and the casing, and the spinning blades fling it onto the walls of the housing.

Most sites get in touch after spotting something like this:

  • A motor area thick with grease
  • Thick grease on the impeller and casing
  • An extract fan with no cleaning record
  • A fan that hums, whines or rumbles

Where a hall near Christ Church Hendon, or anywhere in Brent Cross, hosts lunch clubs or events, its extract gathers grease just as a café’s does.

Comparing quotes

  • When the next visit should be, and why
  • What hours they’ll be on site
  • Whether the figure could change on the day
  • Exactly which parts of the system are covered

How to choose an extract cleaning contractor

Aftercare tips

No system stays clean for ever, but care slows the build-up. Our tips:

  • Make sure the fan is included each time
  • Note any drop in extraction at the canopy
  • Keep records of every fan clean
  • Leave a clear route to the fan

The photo report shows the fan before and after cleaning. It lists what was cleaned and anything we couldn’t reach, along with the recommended next clean date.

Keep the whole system on its cleaning cycle. A fan cleaned with the rest of the system on time rarely gets badly coated, in line with BESA guidance.

BESCA Vent Hygiene EliteMember, cleaning to BESA TR19® Grease
CHAS · SafeContractorISO 9001 and fully insured
Certificate and photo reportWith every clean
24/7 emergency calloutEvenings, nights and weekends
Since 2009South East England and London