Kent · TR19 inspections and grease testing

TR19 Inspection in Plaxtol

TR19 inspections and grease testing for Plaxtol, with a survey first and a report with photos at the end. Ask us for a fixed quote.

  • Pre-clean surveys before a first TR19 clean
  • Extracts that have never been grease tested
  • Kitchens taken over with no cleaning records

TR19 inspection across Plaxtol

Looking after it afterwards

To keep the system working properly between visits:

  • Flag changes in how much frying the kitchen does
  • Keep access panels clear and unpainted
  • Clean grease off the canopy between professional cleans
  • Flag oily drips near the extract

For an insurer audit, send them the report as it is, with readings, photos and any areas not accessible.

When cooking hours or the menu change, check the interval still fits. A quick grease test answers the question.

TR19 inspection in Plaxtol, done properly

A pre-clean survey looks at the whole system, from canopy to discharge. We check where the access panels are and whether every section can be reached, and record grease readings at set points. If you’re dealing with confirming a clean reached the whole system and missing access panels found on survey, we can put it right.

In a village or hamlet like Plaxtol, the kitchens that need extract cleaning are usually a pub, a school, a care home or a hall kitchen, wherever there is one. Each still has a canopy and duct that collect grease.

Accreditations are easy to claim and worth checking. We’re a BESCA Vent Hygiene Elite member, cleaning to BESA TR19® Grease, and we hold CHAS, SafeContractor and ISO 9001, with full insurance on top.

Five Duct Doctor technicians in navy uniforms with the company vans
Place
Plaxtol (TN15)
Region
Kent
Records
Certificate and photo report
Quote
A fixed quote up front
Working hours
Evenings, overnight and weekends; 24/7 emergencies
Phone
0345 646 2711
Last updated
30 October 2026

TR19 inspection around Plaxtol

According to Food Standards Agency records, there are about 3 bars, pubs and nightclubs within 1.5 miles or so of the middle of Plaxtol. Any of them serving cooked food has an extract to keep clean, from canopy to discharge. In Plaxtol, food businesses are inspected by environmental health officers from Tonbridge and Malling council. The cleanliness of the kitchen and its equipment, extraction included, is part of what they check. A TR19® certificate and photo report after each clean gives you a record to show an inspector. Fire safety in Plaxtol falls to Kent Fire and Rescue Service. Its fire safety officers can audit commercial kitchens, and grease in the extract is part of a kitchen’s fire risk.

Where a hall near Plaxtol Church, or anywhere in Plaxtol, hosts lunch clubs or events, its extract gathers grease just as a café’s does. If you look after a school kitchen, at a school such as Plaxtol Primary School or anywhere near Plaxtol, the holidays are the usual time for a TR19® clean.

Plaxtol is about 4 miles north of Tonbridge, in Kent. From the centre of Plaxtol to the outskirts, TR19 inspection is available to all kinds of commercial premises, from small sites to large estates. We cover 922 places across Kent, from busy centres to quieter spots. We also work in Maidstone, around 10 miles away.

TR19 inspection in TN15 is surveyed, quoted and booked the same way as anywhere else. You will find streets such as The Street, St Hildas and Long Mill Lane, and we cover them all for TR19 inspection. Neighbouring places we cover for TR19 inspection include Dunk's Green (1 mile south), Roughway (1 mile south-east), Claygate Cross (1 mile north), Crouch (1 mile north) and Basted (1 mile north). We also work in nearby towns such as Maidstone (10 miles east), Dartford (13 miles north), Sevenoaks (5 miles west), Royal Tunbridge Wells (9 miles south), Gravesend (12 miles north) and Tonbridge (4 miles south).

Landmarks near Plaxtol

In Plaxtol, that means kitchens and buildings near The Kentish Rifleman Public House and Ivy Hatch Nature Reserve and the streets around them. Plaxtol’s nearest station is Borough Green & Wrotham station, about 2.4 miles north. Well-known places in the area include Ightham Court (2.6 miles north) and Sevenoaks Hospital (5.2 miles north-west). Not far away are Barden Lake.

Map of Plaxtol © OpenStreetMap contributors

Signs you need TR19 inspection in Plaxtol

Grease in a duct is flammable fuel. A flare-up on the range can be drawn into the canopy and duct, and from there a fire can spread through the ductwork. Measuring it is the first step to keeping it under control.

Keep an eye out for any of the following:

  • Cleaning intervals that may not suit the kitchen
  • Kitchens taken over with no cleaning records
  • Sections of duct that cannot be reached
  • Extracts that may be over the 200 micron mean

If your kitchen is in a listed or historic building, like the houses around Plaxtol (Old Soar Manor is about 0.7 miles north-east), fitting access panels needs care.

What to look for in a quote

  • Whether a written report and photos are included
  • Whether inaccessible sections are listed on the report
  • Which accreditations they hold, and whether you can check them
  • If they look at the system before pricing

Our hiring checklist

For landlords and multi-site operators

We work for landlords, managing agents and facilities managers as well as the people running the site. Where a system serves more than one tenant, such as a shared riser, it helps to agree who arranges the work, and we can quote for the whole system.

Where a tenant occupies the premises but the landlord owns the building, the lease normally sets out who maintains what. We are happy to deal with either side and send the paperwork to whoever needs it.

How the job changes from site to site

Canopy and plenum

Behind the filters, the plenum catches plenty of grease. We take readings there and photograph it on every inspection.

Vertical risers

Vertical risers take the extract up through the floors. Grease can run down and collect at the base, so the base is a key test point.

Why it’s worth doing now in Plaxtol

If there’s a fire or a claim, your insurer may ask for TR19 records. Without them, a claim can be reduced or refused. An up-to-date inspection report is a good place to start. If the system at a site near Plaxtol fails, there may be nowhere nearby to move to.

You won’t find a price list here, because each job is priced on what it involves. Call for a fixed quote, and we will explain what it covers.

What you get with us

  • We are fully insured
  • CHAS and SafeContractor accredited, with ISO 9001
  • A written report with photos after every visit
  • A fixed price before any work starts

See what affects the cost and our accreditations and certificates.

Common questions in Plaxtol

Do you clean school canteen extracts around Plaxtol out of term?

Yes, out-of-term visits are normal for schools. Food Standards Agency records list about 2 schools, colleges and universities with registered kitchens within about a mile and a half of Plaxtol. Send us your term dates when you phone us on 0345 646 2711 or use the quote form, and we’ll fit the work in.

Can you come to Plaxtol after we close?

Yes. We work evenings, overnight and at weekends. The site is handed back ready to open. Tell us your opening hours when you ask for a quote.

Do you work with multi-site operators?

Yes. Our area covers London and the South East, so sites at different addresses can be planned together on one programme. Every site has its own report.

How much time does an inspection need?

Expect it to take a morning or less for one kitchen, more where there are several systems. We fit it around when the kitchen is closed or quiet.

Why survey before a clean?

We look at the system from canopy to discharge, take grease readings and check access. From it, we plan the clean and quote a fixed price.

What happens if you cannot reach some of it?

Anything we can’t reach goes on the report, with photos where possible, and we explain what access is needed, such as extra access panels in ductwork.

Do you cover Plaxtol?

Yes. We work in Plaxtol and the rest of Kent, as part of our work across South East England and London. To book, call 0345 646 2711 or send us an email.

How do you measure grease in a kitchen extract?

We measure the grease at set points with a WFTT or DTT test, then compare them with the TR19® Grease figures.

What we do, step by step

The visit has three parts: getting the area ready, doing the work and signing it off. Getting ready means protecting surfaces and switching off what needs to be off, while signing off means the written report and photos. Most of the time goes on the work itself, which takes a morning or less for one kitchen, more where there are several systems. We agree a date with you, plan the drive to Plaxtol and turn up when the site is quiet.

  1. First we look at the system’s cleaning history, if there is one.
  2. We follow the extract from canopy to discharge.
  3. We note where access panels are and where more are needed.
  4. Grease readings are taken and pictures recorded.
  5. You get a report and a fixed quote for the clean.

Preparing for the visit

  • Mention any sign-in, permit or induction we need
  • Make sure equipment near the work can be switched off and left to cool
  • Make sure someone can let us in and lock up afterwards

How to get a quote

Photos are enough for some jobs, while others need a look on site. Big or complicated sites, and systems that are hard to see in pictures, get a survey first. Either way, the quote is fixed before any work is booked.

Get a quick quote

Related advice

What a clean will not put right

An honest diagnosis matters more to us than a booking, so here’s what this work cannot put right:

  • A faulty or failing extract fan
  • Fire safety duties beyond the extract system
  • Heavy deposits found on test, which still need cleaning

Not sure which it is? You can call 0345 646 2711 or use the quote form and we will tell you honestly.

Where we work

  • Wet film thickness tests
  • Post-clean checks
  • Pre-clean surveys
  • Access surveys
  • Deposit thickness tests
  • Insurer audits
BESCA Vent Hygiene EliteMember, cleaning to BESA TR19® Grease
CHAS · SafeContractorISO 9001 and fully insured
Certificate and photo reportWith every clean
24/7 emergency calloutEvenings, nights and weekends
Since 2009South East England and London